Skip to content

Water modes against observed fundamentals

How far does PBE/def2-SVP miss the three observed vibrational fundamentals of an isolated water molecule? The model is gas-phase H₂O, neutral singlet, relaxed with PBE/def2-SVP. Its analytical Hessian gives the frequencies.

Build script · Run script

The starting geometry is the builder molecule. The build step writes it as an extxyz file and uses no calculator.

from atomli.build import molecule
from atomli.io import write
write("h2o-start.extxyz", molecule("H2O"))

Starting water molecule from the builder

The run step reads the file, relaxes it to a maximum force of 0.003 eV/Å and takes the analytical Hessian. The three vibrational modes are the highest frequencies; the six rigid-body modes lie below.

from atomli.io import read
from atomli.calculators.qc import QC
from atomli.optimize import BFGS
from atomli.vibrations import Vibrations
atoms = read("h2o-start.extxyz")
atoms.calc = QC(xc="PBE", basis="def2-SVP")
BFGS(atoms).run(fmax=0.003)
frequencies = Vibrations(atoms).run().get_frequencies() # analytical Hessian
O–H bond
0.975Å
H–O–H angle
102.05°
Zero-point energy
0.564eV
Largest error
32.8cm⁻¹

Computed (bars) against observed (diamonds). The number above each pair is computed minus observed, in cm⁻¹.

Computed (bars) against observed (diamonds). The number above each pair is computed minus observed, in cm⁻¹.

Normal mode, amplitude exaggerated:

Normal mode, amplitude exaggerated: bend

ModePBE/def2-SVP (cm⁻¹)Observed (cm⁻¹)Error (cm⁻¹)Error (%)
bend1608.41595.013.40.8
symmetric stretch3689.73657.032.70.9
antisymmetric stretch3788.83756.032.80.9

Computed: atomli QC, PBE/def2-SVP, geometry relaxed to fmax 0.003 eV/Å, analytical Hessian.Observed: gas-phase H2O fundamentals from Shimanouchi, NSRDS-NBS 39 (1972).

PBE/def2-SVP puts the bend 13.4 cm⁻¹ above the observed fundamental and the two stretches 32.7 and 32.8 cm⁻¹ above theirs. The stretch splitting is 99.1 cm⁻¹ against 99.0 observed. The Hessian gives harmonic frequencies and the observed values are anharmonic fundamentals, so part of every difference is anharmonicity, not functional error.

study.json holds every number on this page.

Terminal window
python python/water-modes-build.py --output models
python python/water-modes-run.py --models models --output studies/water-modes